logo

products details

Created with Pixso. Created with Pixso. 상품 Created with Pixso.
지국 피뢰기
Created with Pixso.

Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing

Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing

MOQ: 1
가격: 1
Detail Information
인증:
ISO9001
모델 번호:
Hy5WBG-17/50
설치 유형:
병렬 어레스터
재료:
Zno
주택 자료:
중합체
전압 등급:
17kV
방전 전류:
5KA
정격 전압:
17 kV
연속 전압을 작동합니다:
13.6kV
최대 직류전압:
25 kV
최소 가파른 충동:
57.5 kV
최대 번개 충동:
50 KV
최대 작동 충동:
42.5 kV
지속 전류:
0.5 마
저항 전류:
250 uA
굽는 저항:
1.6 kN
강조하다:

17kV polymer surge arrester

,

outdoor brace-type lightning arrester

,

HY5WBG-17/50 surge protector

Product Description
Outdoor Line Class Brace-Type Surge Arrester (HY5WBG-17/50)
Product Specifications
Attribute Value
Model NO. HY5WBG-17/50
Installation Parallel Arrester
Application Substation
Size Medium
Operation Voltage Low Voltage
Shape Cuboid
Material ZnO
Brand Yongde
Housing Color Grey
Housing Polymer
Voltage 17kv
Discharge Current 5ka
Transport Package Carton
Specification GB IEC
Trademark YongDe
Origin China
HS Code 85354000
Production Capacity 50,000 PCS/Year
Product Description
Brace-Type Surge Arrester
Operating Conditions
  • Suitable for both outdoor and indoor operation
  • Maximum altitude: 2000m
  • Power frequency range: 48Hz to 62Hz
  • Power frequency voltage must not exceed arrester's continuous operative voltage
  • Maximum earthquake intensity: 7 degree
  • Maximum wind speed: 35m/s
Construction Features and Operation Principle

The arrester features non-linear high-quality metal oxide varistor internals with a silicone rubber molded exterior.

Under normal conditions, the surge arrester maintains high resistance with only microampere current flow, ensuring no impact on equipment operation. During overvoltage events, the arrester switches to low resistance, conducting kilo-ampere current while maintaining voltage within safe limits to protect connected equipment.

Technical Specifications
Type Rated Voltage (KV) Operate Continuous Voltage (KV) Maximum DC 1 mA Reference Voltage (KV) Minimum Steep Impulse Residual Voltage (KV) Maximum Lightning Impulse Residual Voltage (KV) Maximum Operation Impulse Residual Voltage (KV) Persistent Current (MA) Resistive Current (UA) Bending Resistance (KN) Bending Broken (KN)
HY5WBG-17/50 17 13.6 25 57.5 50 42.5 0.5 250 1.6 4
Product Images
Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 0 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 1 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 2 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 3 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 4 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 5 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 6 Outdoor Brace-Type Surge Arrester HY5WBG-17/50 17kV Polymer Housing 7